AGNI Fire Alarm Fire Alarm Extinguisher, Smoke Detector Equipment



Panels….
AGFORIEL6Z
Conventional Panel
Panel
6 Zone Panel, 2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone

AGFORIEL8Z
Conventional Panel
Panel
8 Zone Panel with LCD Display, 2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone

AGFORION2Z
Conventional Panel
Panel
2 Zone Panel ,2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone

AGF2ZECO
Conventional Panel
Panel
2 Zone Panel ,2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone

AGFORIEL10Z
Conventional Panel
Panel
10 Zone Panel with LCD Display,2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone

AGFORIEL12Z
Conventional Panel
Panel
12 Zone Panel with LCD Display, 2*16 character backlit LCD Display, complies to IS 2189:1999 and tested by ERTL (N) & System sensor, Lamp test feature, complete with integral power and battery charger for sealed lead acid battery, potential free contacts for both fire and fault, Short circuit, Isolate, Fire in each Zone


Sensors—from system sensor
SSF2351EC
Conventional Detector
Smoke Detector
Photoelectric Smoke Detector,Low profile design, Low current draw,Wide operating voltage 8 to 30VDC, Bi-colour LED detector status indicator, Automatic drift compensation,Programmable sensitivity,Advanced maintenance features via remote hand-held test unit,Tested and approved to EN54 – 7:2000

SSF2351TEM
Conventional Detector
Other Detector
Photoelectric Smoke/Thermal Detector , Low profile design, Low current draw,  Wide operating voltage 8 to 30V, Bi-colour LED detector status indicator, Automatic drift compensation, Programmable sensitivity, Advanced maintenance features via remote hand-held test unit,


SSF5351E
Conventional Detector
Other Detector
Rate of Rise Thermal Detector, Low profile design, Low current draw, Wide operating voltage 8 to 30VDC, Bi-colour LED detector status indicator, Programmable sensitivity, Advanced maintenance features via remote hand-held
test unit

SSFB401
Conventional Detector
Detector Base
2 Wire plug in detector base for Series 300 detectors